hit counter script

Motor Electronic (Speed Control Board); S 3Xx; S 4Xx; Motor Brushes - Miele S 247i Technical Manual

Table of Contents

Advertisement

S 2xx, S 3xx & S 4xx Canister Vacuums

Figure 5-36: S 4xx Motor with Central Bearing

5.19

Motor Electronic (Speed Control Board)

5.19.1

S 3xx

1. Remove the motor (Section 5.18).
2. Depending on model, either remove the 2 Phillips screws securing the
electronic or pull out the electronic from its plug connections.
5.19.2

S 4xx

1. Remove the 2 Phillips screws securing the electronic.
2. Pull out the electronic from its plugs on the motor.
5.20

Motor Brushes

5.20.1
S 3xx
1. Remove the motor (Section 5.18).
2. Pull off the rear holding plate on the motor.
3. Remove 2 screws from each brush.
4. Remove the brushes.
Note:
When the brushes need replacing, both must always be changed at the same
time.
5.20.2
S 4xx
1. Remove the motor holder (Figure 5-36, Item 2).
2. Unscrew the Torx screws from the brush holders. Unplug and remove the
brush holders.